Biogas

Installations for the injection of gas into the network according to the source pressure, destination and flow rate: compression line, regulation line, valve position (injection/rejection), chromatography to determine supply quality, metering line according to distribution indications, redundant systems, control system, SCADA, remote access, dispatching communication.

CNG supply installations for self-consumption, connected to pipeline or supplied with CNG. Stations sized according to needs, plant production capacity, existing parallel consumption and expected NGV demand.

CNG mother compression plants for filling CNG transport trucks.

Facilities for storing surplus gas in the network when the network pressure exceeds a certain value and subsequent delivery of the accumulated surplus gas when the network pressure drops below a certain value. (Compression/storage/decompression).

Supply of biogas distributed in trucks and from mother stations for supply to towns and industrial establishments.